This series of panels were manufactured in the mid ’80′s until the mid ’90′s. If your home has this keypad the system is more than 12 years old, 2 years older than the recommended lifespan of an alarm system. Below is a link to the user’s manual and basic troubleshooting problems. Unfortunately because of the age the recommended course of action may be to replace the whole system.
To replace your hardwired system it will cost $250.00 and set up of electronic payment.
To replace your wireless system see the new sales options. You will not increase your monitoring rate, you only must set up electronic payment. Notice that wireless alarms have reduced significantly since the first time you purchased your current system.
Click here to access the User’s guide.
Change Master Code- *5, Old Master Code, 40, __ __ __ __ (new code) Will beep to confirm, ## to exit
Additional User Codes- *5, Master Code, 01-32, __ __ __ __(new code), Will beep to confirm, ## to exit
Arm- Enter your 4-digit master code or any previously programmed user code. The panel will take 60 seconds to arm, if no doors are opened at this time the panel will arm in Stay Mode with the motion detectors off, if a door is opened then the panel will arm in Away Mode with the motion detector on.
Turn Off- Enter your 4-digit master code or any previously programmed user code.
Chime- * 4. Toggle on and off.
Reset- For Hard-wired Smoke detectors- In most homes this button is not in use
Exit- Allows for a brief 30sec disarmed period while panel is set to away, for the door to open one time, great if you want to go out early in the morning and not wake anybody else in the home up.
Bypass- To bypass a zone press *1, then the 2-digit zone number (ex: 03) you wish to leave open while arming the rest of the system. Will remain bypassed for one arming/disarming cycle
System Time- *6, Master Code, 1,enter time in 24hr clock: HHMM MMDDYY ## to exit.
(Ex: 4pm the 22nd of March 2010 will be: 1600032210)
Trouble Light- press *2- The 1 through 8 light will light up.
1- There is a problem with battery and/or siren, Call us to clear trouble.
2- AC Loss, the panel is running on battery and requires AC power to return to clear trouble.
3- Loss of Dial tone on phones, either telephone company is not providing signal to the house or there is a wiring problem. Check home phones, if they work, call us to clear trouble, if they do not work, call your phone Provider. For Cell Primary customers, call us to clear trouble.
4- Failure to communicate- If no 3 is present call us to clear trouble, if 3 is present follow troubleshooting for 3.
5- Fire Detector Fault- Contact us to clear trouble.
6- Wireless Zone Fault- Press 6, the number that comes up is the faulting zone, press on sensor to make sure it is snapped shut, then open and close zone 2 times, if this doesn’t clear trouble contact us.
7- Wireless Zone low battery- press 7, the number that comes up has a low battery, either replace battery on your own or contact us to replace battery. You have less than 7 days from time of fault to replace the battery.
8- Loss of System time – follow instructions for setting system time above.